6 Commissioning and Operation

Warning:
-
High voltage electricity can be dangerous for people with pacemakers.
-
Avoid contact with live parts of the charging electrode which may cause an
unpleasant electric shock.
Consult the manual of the high voltage generator for the commissioning and operation of the
generator.
- Turn the power off.
- Check that all wires and electrodes of the charging system are installed correctly.
- Verify that all unused inputs and outputs are sealed with a plug.
- For optimal charging, high voltage value and cycle time will have to be set for each
application, label size and number of electrodes. These settings will have to be determined
from experience.
- Depending on the electrode installation, the high voltage generator can overload if there is no
label present between the charging electrode and ground while the high voltage is switched
on.
- It is recommended to set the voltage first to 3 kV and increase it later.
- Switch the high voltage on once the electrode and a label have been fitted into the mould.
The label should jump off the dummy core and stick to the metal mould.
- Increase the high voltage until the label sticks properly. Set the high voltage approx.10%
higher than the standard value in order to compensate for process fluctuations. Do not set to
unnecessary high values in order to prevent wear on the electrodes.