5.3 IML Spider Junction Block Mounting and connecting
The number of connecting cables, Junction Blocks, IML Spiders and the number of electrodes
varies per application.
The IML Spider and the Junction block must be mounted within the range of the connection
cables and the electrodes.
Consult the manual of the high voltage generator used for connecting the IML Spider
components to the generator.
- Mount the IML Spider or the Junction Block on a stable machine component or at the end of
the IML robot arm using the four provided ø5,5 mm holes in the assembly flange of the
covering.
- Fit the IML Spider Head or the J-Block Head to the CMM Easy and lock them down. See
CMM Easy user's manual.
- Connect the components of the IML Spider charging system to each other by plugging the
connection cables into matching input and output sockets.
- Close off any unused input and output sockets on the IML Spiders and the Junction Blocks
using the plugs provided.
- Use the mounting clamps provided to fasten the connecting cables and electrodes. Fit the
strips at about 15 cm from cable connections. NOTE: do not fasten any cables or electrodes
on the strips where metal mounting screws have been used.