D according to EN 795. The device and the movable anchor point must be
able to align themselves freely.
Before and during each use, make sure that the required ground clearance
H
is, in any case, sufficient to ensure the effectiveness of the system and
Li
to avoid impact with the floor or other obstacles (Fig. 5):
Braking distance of the SRL Δl (max. 2.0 m)
+ safety distance (1 m)
+ if necessary, additional height of 0.6 m (when working with a lateral
offset of max. 1.5 m)
+ if necessary, deflection of the other system components (observe the
corresponding instructions for use of the manufacturer).
Weight limits:
all variants: 40 - 140 kg
4) Horizontal use (only RAPTOR C6/ C10/ C20)
The SRL can be used for horizontal use regardless of the layer. The edge
suitability was proven by drop tests over a grade-free edge made of steel with
a radius r = 0.5 mm. Based on these tests, the variants RAPTOR C6, C10
and C20 are applicable in case of a fall over an edge. If there is a risk of falling
over an edge, the following must be considered regardless of these tests:
• If the risk assessment carried out before starting work shows that the
edge is particularly „sharp" (r < 0.5mm) and/ or „not free of burrs", it
must be
• a fall over this edge is prevented by technical or organisational mea-
sures, or
• an edge protector is fitted and used or
• contact is made with the manufacturer.
• The anchorage point must not be below the user's standing surface,
e.g. on a roof or platform.
• The deflection at the edge must not exceed 90°.
• Slack rope is to be avoided.
• When working laterally offset to the anchor point up to max. 1.5 m,
care must be taken to minimise the risk of a pendulum fall. If this is not
possible, use other suitable anchorage devices, e.g. EN 795 type C
(combination must be tested) or D.
• For the calculation of the required ground clearance (H
edge, the information in Fig. 6 must be observed. Note: When used
with an EN 795 type C anchorage system, the combination must have
been officially tested and the deflection of this system must be taken
into account when calculating the required ground clearance H
event of a fall. The information in the corresponding instructions must
be observed.
• Note: In the event of a fall over an edge, there is a risk of injury to the
user through contact with the building / structure.