3.2
Care and treatment of the front cover
The front plate can be cleaned with commercial detergents and cleaning agents.
3.3
Mounting site, DIN-rail mounting
Warning
The device is not suitable for installation in potentially explosive areas.
The device is clipped to a 35 mm DIN rail (DIN EN 60715) from the front
and locked into place by pressing downwards.
-
The ambient conditions at the mounting site must meet the requirements
specified in the technical data.
v
Chapter 6 "Technical data"
-
Ensure vibration-free installation to prevent the screw connections from
working loose!
-
The atmosphere must be free from aggressive media (e.g., strong acids
and lyes), as well as free from dust, flour, or other suspended solids to pre-
vent blocking of the cooling slots!
3.4
Close mounting
-
Maintain the minimum distance of 20 mm to the top and the bottom.
1. So that the release slot can still be accessed with a screwdriver from the bottom.
2. So that when dismounting, the device can be swiveled upwards and removed from the DIN rail.
-
Several devices can be mounted right next to one another without a minimum distance.