3.3.2 Cylinder placement and connecting the gas hose
• Position the cylinder on the cylinder holder of the
welding machine, using the straps provided to fasten it to
the rear panel of the machine.
• Periodically check for wear on the straps, and order
replacements if necessary.
• the cylinder must be equipped with a pressure regulator
complete with flow gauge.
• only after positioning the cylinder, connect the outgoing
gas hose from the rear panel of the machine to the
pressure regulator.
• Adjust the gas flow to approximately 10/18 liters/minute.
3.3.3 Connecting the wire feeder
this power source accepts the wire feeders art.1652 and art.
1662. to connect the power source and wire feeder, use the
extension art. 1182 (5 m) or art. 1182.20 (10 m).
the performance and operating options of the wire feeder are
described in the instructions enclosed with the wire feeder itself.
4 DESCRIPTION Of CONTROLS
4.1 CONTROLS ON ThE fRONTOf ThE MAChINE.
c
a
A - Selector switch
1
8
2
Fine-tunes the welding voltage within
the range previously selected via
selector switch S.
7
3
6
4
5
Fig. 6
2
3
1
0
C - Switch
turns the machine on or off.
1
V
D- Earth sockets.
sockets to which to connect the earth cable.
4.2 CONTROLS ON gENERATOR REAR PANEL
B
e
d
h
F
g
Fig. 7
E - 230V power supply socket.
440 W max. power. For cooling unit only. (warning: Do
not connect other equipment to this socket.).
f - 6-pin socket connector.
For the 6-pin plug connector on extension lead.
B- Selector switch
select the ranges of welding voltage.