vents; these may be aggressive to the plastic parts in
the equipment. Ensure that no water can get into the
interior of the equipment.
• In order to extend the service life of the tool, oil the
rotary parts once monthly. Do not oil the motor.
Brush inspection
In case of excessive sparking, have the carbon brushes
checked only by a qualified electrician. Important. The
carbon brushes should not be replaced by anyone but a
qualified electrician.
Storage
Store the device and its accessories in a dark, dry and
frost-proof place that is inaccessible to children. The
optimum storage temperature is between 5 and 30˚C.
Store the electrical tool in its original packaging.
Cover the electrical tool in order to protect it from dust
and moisture.
When the sawblade and key are not in use, they can
be stored as in fig 23.
Store the operating manual with the electrical tool.
Electrical connection
The electrical motor installed is connected and
ready for operation. The connection complies with
the applicable VDE and DIN provisions.
The customer's mains connection as well as the
extension cable used must also comply with these
regulations.
Important information
In the event of an overloading the motor will switch
itself off. After a cool-down period (time varies) the mo-
tor can be switched back on again.
Damaged electrical connection cable
The insulation on electrical connection cables is often
damaged.
This may have the following causes:
• Passage points, where connection cables are
passed through windows or doors.
• Kinks where the connection cable has been improp-
erly fastened or routed.
• Places where the connection cables have been cut
due to being driven over.
• Insulation damage due to being ripped out of the
wall outlet.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insulation
damage.
Check the electrical connection cables for damage regu-
larly. Make sure that the connection cable does not hang
on the power network during the inspection.
Electrical connection cables must comply with the ap-
plicable VDE and DIN provisions. Only use connection
cables with the marking „H05VV-F".
The printing of the type designation on the connection
cable is mandatory.
AC motor
• The mains voltage must be 230 V~
• Extension cables up to 25 m long must have a
cross-section of 1.5 mm
.
2
Connections and repairs of electrical equipment may
only be carried out by an electrician.
Please provide the following information in the event of
any enquiries:
Type of current for the motor
24 І 28
24 І 28
 www.scheppach.com  service@scheppach.com  +(49)-08223-4002-99  +(49)-08223-4002-58
 www.scheppach.com  service@scheppach.com  +(49)-08223-4002-99  +(49)-08223-4002-58
• Machine data - type plate
• Machine data - type plate
Recycling
The packaging is made of environmentally friendly
materials. It can be disposed of at your local recycling
centre.
Old devices must not be disposed of with
household waste!
This symbol indicates that this product must
not be disposed of together with domestic
waste in compliance with the Directive
(2012/19/EU) pertaining to waste electrical
and electronic equipment (WEEE). This
product must be disposed of at a designated collec-
tion point. This can occur, for example, by handing it
in at an authorised collecting point for the recycling
of waste electrical and electronic equipment. Improp-
er handling of waste equipment may have negative
consequences for the environment and human
health due to potentially hazardous substances that
are often contained in electrical and electronic equip-
ment. By properly disposing of this product, you are
also contributing to the effective use of natural re-
sources. You can obtain information on collection
points for waste equipment from your municipal ad-
ministration, public waste disposal authority, an au-
thorised body for the disposal of waste electrical and
electronic equipment or your waste disposal com-
pany.
Environmental protection
Take any contaminated maintenance material and
operating materials to a collection point designated
for this purpose.
When disposing of residual fluids (oils and fuel), ob-
serve the corresponding environmental regulations.
We recommend taking all remaining operating mate-
rials to your local collection point in a suitable sealed
container. Do not pour the remaining operating ma-
terials into waste or on the ground.