Herunterladen Diese Seite drucken

Lenze Servo Drives 930 fluxxtorque Montageanleitung Seite 68

Vorschau ausblenden Andere Handbücher für Servo Drives 930 fluxxtorque:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

4
Electrical installation
Electrical connections 931MxNx1
4.4
Electrical connections 931MxNx1
X2 voltage supply
Contact pattern
X1 RS232
Contact pattern
X5 digital input, digital output (option)
Contact pattern
68
Pin No. Value
1
DC 0 V (N for AC supply)
2
DC + 320 V
3
AC 230 V
PE
PE
A
DC + 24 V
B
GND
C
GND
D
DC + 24 V
Pin no.
Signal
1
TxD
2
GND (ground)
3
RxD
Pin No. Signal
Function
1
DC + 24 V
2
DIN0
Digital input 0
3
GND
4
DOUT0
Digital output 0
Specification
Voltage supply
DC voltage supply
AC voltage supply
Earth and shielding
Brake voltage supply
Auxiliary supply of reference
potential
Brake enable (low active)
Auxiliary voltage supply
Specification
Control voltage DC + 24 V ± 10 %
Rated voltage
HIGH signal
LOW signal
Cycle time
Reference potential for control voltage
Output voltage
LOW signal
HIGH signal
Output current
Cycle time
Short−circuit−proof
l
DC + 24 V
DC 18 ... 30 V
DC 0 ... 4 V
Maximally 0.5
ms
DC + 24 V
DC 0 ... 4 V
DC 18 ... 30 V
Maximally 0.5 A
Maximally 0.5
ms
MA 13.1002 DE−EN DE/EN 1.1