CAUTION
Scalding from hot lubricant
Danger of scalding when draining lubricant if it comes into contact with the skin.
► Wear protective equipment.
► Use a suitable collection receptacle.
Pfeiffer Vacuum recommends determining the precise service life of the lubricant in
the first operating year.
The usable life may deviate from the reference value specified depending on thermic and
chemical loads, or due to penetrating process media in gear and bearing chambers.
Safety data sheets
You can obtain the safety data sheets for lubricants from Pfeiffer Vacuum on request, or
from the
Pfeiffer Vacuum Download
Consumable
● Lubricant
Required tool
● Ring spanner, WAF 24 mm
● Calibrated torque wrench (tightening factor ≤ 2.5)
1
5
Fig. 16:
Changing the lubricant
1 Lubricant filling plug
2 Lubricant filling plug
3 Lubricant drain plug
Drain the lubricant
Consult with Pfeiffer Vacuum Service about shorter maintenance intervals for extreme loads or impure
processes.
1. Shut down the vacuum pump and allow it to cool if necessary.
2. Vent the vacuum pump to atmospheric pressure via the intake side.
3. Unscrew the lubricant filler screws.
4. Place the collection receptacle underneath.
5. Unscrew both lubricant filler screws.
6. Fully drain the lubricant.
7. Screw the drain screws back in.
– Tightening torque: max. 50 Nm