Herunterladen Diese Seite drucken

Agilent Technologies Turbo-V 2000HT Betriebsanleitung Seite 79

Vorschau ausblenden Andere Handbücher für Turbo-V 2000HT:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 11
Connection P1
Logic Input Interconnections
P1 input connector
All the logic input to the controller must be connected at
J-1 mating connector. With the provided J1 mating
connector (shipped with pin 3 and pin 8 shorted) make
the connections with AWG 24, (0.24 mm ) or smaller
wire to the pins indicated in the figure to obtain the
desired capability. The following table describes the
signals available on the connector.
PIN
DESCRIPTION
1-6
Remote START/STOP optically isolated from
the internal circuit, requires a
closed contact (relay contact transistor, etc. ).
When the contact closes. the turbopump
starts, and when the contact opens. the
turbopump is stopped. With the remote mode
operation selected, the front panel push-
button is inoperative.
2-7
Remote LOW SPEED optically isolated from
the internal circuit, requires a permanently
closed contact (relay contact, transistor. etc.).
When the contact closes, the turbopump runs
at low speed and when the contact opens, the
turbopump reverts to high speed mode. With
the remote mode operation selected, the front
panel push-button is inoperative.
3-8
INTERLOCK
optically
internal circuit, this signal can be used to
delay
the
starting
requires a permanent closed contact before
starting the turbopump.
4-9
SYSTEM OVERRIDE optically isolated from
the internal circuit, this signal is used to stop
the pump in emergency condition, requires a
closed contact.
When the contact is closed, the turbopump
and the interconnected devices are stopped.
permanently
isolated
from
the
of
the
turbopump.
Pin
3-8
must
Turbo-V 2000HT pump to start if no interlock contact is
connected. if, after starting the pump, the interlock
contact opens, it has no effect on the operation and the
pump continues to turn.
The following figure shows a typical contact logic input
connection and the related simplified circuit of the
controller.
Typical logic input connection
Connection J2
Logic Output Interconnections
Logic output connector
All the logic output from the controller must be
connected at P2 mating connector. With the optional
P2 mating connector make the connection with AWG
24 (0.25 mm) or smaller wire to the pins indicated in the
figure to obtain the desired capability. The following
table describes the signals available on the connector.
73
TECHNICAL INFORMATION
NOTE
be
shorted
to
allow
87-900-913-01 (N)
the

Werbung

loading

Diese Anleitung auch für:

969-9462969-9562