Herunterladen Inhalt Inhalt Diese Seite drucken

HBM RM220 Bedienungsanleitung Seite 11

Dms-verstärker
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

RM4220
Connection with four‐wire configuration (factory setting)
4
Exc +: Excitation voltage (+) for trans­
ducer
5
Signal +: Measurement signal (+)
6
M; no function, but do not use terminal
7
-
8
Exc -: Excitation voltage (-) for trans­
ducer
Terminal
9
V +
10
11
V
out
12
GND
13
GND
14
15
I
out
16
GND
Connection with six‐wire configuration (see Section 5.2, Page 13)
Terminal
1
Signal -: Measurement signal (‐)
2
3
Sense +: Sense lead (+)
4
Exc +: Excitation voltage (+) for trans­
ducer
5
Signal +: Measurement signal (+)
6
M; no function, but do not use
terminal
7
Sense -: Sense lead (-)
8
Exc -: Excitation voltage (-) for trans­
ducer
Terminal
9
V +
10
11
V
out
12
GND
13
GND
14
15
I
out
16
GND
A1091-4.0 en/de
Function
Function
Function
BU (blue)
WH (white)
BK (black)
External connections
Supply voltage + (+16 V ... +32 V)
Cable shield, preferable for voltage output
cable or for supply voltage cable shield
Voltage output
GND, preferable for voltage output
Supply voltage -
Cable shield, preferable for current output
cable or for supply voltage cable shield
Current output
GND, preferable for current output
Color of transducer connection
(HBM cable with six‐wire configuration)
RD (red)
Cable shield / Drain wire
GN (green)
BU (blue)
WH (white)
GY (gray)
BK (black)
External connections
Supply voltage + (+16 V ... +32 V)
Cable shield, preferable for voltage output
cable or for supply voltage cable shield
Voltage output
GND, preferable for voltage output
Supply voltage -
Cable shield, preferable for current output
cable or for supply voltage cable shield
Current output
GND, preferable for current output
11
HBM

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis