Herunterladen Diese Seite drucken

IFM Electronic ecomat 100 R 360 Serie Montage- Und Installationshinweise Seite 18

Vorschau ausblenden Andere Handbücher für ecomat 100 R 360 Serie:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

CR0015
Output error
Relay output
Input/output types
Scale drawing
43
page 18
semiconductor output; short-circuit and overload
protected
switching voltage
switching current
overload current
internal relay output
normally open contact in series with (max.12) semi-
conductor outputs for electrically isolated switch-off.
Permanent forced hardware control and additional
control by user program (for further information see
hardware description chapter 2.)
The relay should on principle be switched without
load.
switching current
overload current
number of operating cycles (without load)
switching time constant
input low-side
+U B
sensor
GND
output low-side
+U B
GND
LED
5,5
11 ... 32V
10mA ... 100mA
0.5A
input high-side
+U B
sensor
GND
output high-side
+U B
load
225
100mA ... 15A
20A
≥ 10
6
≤ 3ms
load
GND
26
20
15

Werbung

loading

Diese Anleitung auch für:

Cr0015