CR0015
2. Technical data
Housing
Housing dimension
Mounting position
Connection of the unit
Operating temperature
Storage temperature
Protection rating
Protection class
Air humidity
Supply voltage
Power consumption
Processor
Display
Device monitoring
Memory
Interface
page 16
closed, screened metal housingwith flange fastening
225 x 153 x 43mm (WxHxD), without connector
240 x 153 x 43mm (WxHxD), with connector
preferably vertical, alternatively horizontal
55-pin connector, latched, protected against reverse
polarity AMP-type housing with crimp connection
contacts AMP junior timer 0.5/2.5mm
-40°C ... +85°C
-40°C ... +90°C
IP 67
(protection for connector, depending on cable version)
III
≤ 90% rel. air humidity, not condensing
(perm. height 2000m)
U
nominal 24V DC (20...30 V DC)
B
Residual ripple:
Reset in case of undervoltage: ≤ +12,0 V
Overvoltage:
approx. 10VA, without external load
CMOS-microcontroller C 167 C
three-colour LED red/green/orange for indication of
status and error
8-bit microcontroller to monitor the C 167 C
(extended watchdog function)
undervoltage and overvoltage monitoring
check sum test for program and systemexcess
temperature monitoring
256 kByte program memory
64 kByte data memory
256 Byte auto-Save data memory (protected against
voltage failure)
Full CAN Bus, version 2.0 (ISO/DIS-11898)
Baud rate: 10kBit/s ... 1MBit/s
Device class: CANopen:
CAN:
Serial interface RS 232 C, 9.6kBaud
No. of participants: 2
2
≤ 1,5 Vpp, f ≤ 50 Hz
≤ +36,0 V for t ≤ 10 s
master/slave
Full CAN

Werbung

loading

Diese Anleitung auch für:

Cr0015