Herunterladen Inhalt Inhalt Diese Seite drucken

Dmx-Controlled Operation; Addressing; Dmx-Protocol - EuroLite LED DMS-2 RGBAW Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

DMX-CONTROLLED OPERATION

You can control the LED DMS-2 RGBAW individually via your DMX-controller. Connect the device to the
controller.
Every DMX-channel has a different occupation with different features.

Addressing

Each device occupies 8 channels. To ensure that the control signals are properly directed to each device,
the device requires addressing. This is to be adjusted for every single device by changing the DIP-switches
as set out in the table below.
The starting address is defined as the first channel from which the device will respond to the controller.
Please make sure that you do not have any overlapping channels in order to control each device correctly
and independently from any other fixture on the DMX data link. If two, three or more devices are addressed
similarly, they will work similarly.
Occupation of the DIP-switches:
Controlling:
After having addressed all LED DMS-2 RGBAW devices, you may now start operating these via your lighting
controller.

DMX-protocol

Channel 1 ~ Scanning
Value:
Characteristic:
001 – 255
Left mirror, 128 is center
Channel 2 ~ Scanning
Value:
Characteristic:
001 – 255
Right mirror, 128 is center
21/24