Herunterladen Inhalt Inhalt Diese Seite drucken

Dmx-Controlled Operation; Addressing - EuroLite LED TMH-90 Moving-Head Wash Zoom Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

DMX-controlled operation

You can control the projectors individually via your DMX-controller. The device has two different DMX
channel modes. Every DMX-channel has a different occupation with different features. The individual
channels and their features are listed under DMX-protocol.

Addressing

The Control Board allows you to assign the DMX starting address, which is defined as the first channel from
which the LED TMH-90 will respond to the controller.
If you set, for example in the 24 channel mode, the address to channel 25, the fixture will use the channels
25 to 48 for control.
Please, be sure that you don't have any overlapping channels in order to control each LED TMH-90 correctly
and independently from any other fixture on the DMX-chain. If several LED TMH-90 are addressed similarly,
they will work synchronically.
Press the Up/Down-buttons for setting the desired starting address. Now you can start operating the LED
TMH-90 via your lighting controller.
Note:
After switching on, the device will automatically detect whether DMX 512 data is received or not. If the data
is received, the status indicator to the right of the display will be flashing. If there is no data received at the
DMX-input, the status LED does not flash.
This situation can occur if:
- the 3 PIN XLR plug (cable with DMX signal from controller) is not connected with the input of the device.
- the controller is switched off or defective, if the cable or connector is defective or the signal wires are swap
in the input connector.
The LEDs of the device are arranged as shown in the graphic.
30/36
00091420.DOC, Version 1.0

Werbung

Inhaltsverzeichnis
loading