Caution: At the last fixture, the DMX-cable has to be terminated. Plug the terminator with a 120
between Signal (–) and Signal (+) in the DMX-output of the last fixture.
Master/Slave operation
The master/slave operation enables that several devices can be synchronized and controlled by one master
device.
On the rear panel of the device you can find an XLR jack and an XLR plug, which can be used for
connecting several devices.
Choose the device which is to control the effects. This device then works as master device and controls all
other slave devices, which are to be connected to the master device via a DMX-cable. Connect the OUT jack
with the IN plug of the next device.
Connection with the mains
Connect the device to the mains with the enclosed power supply cable.
The occupation of the connection-cables is as follows:
Cable
Pin
Brown
Live
Blue
Neutral
Yellow/Green
Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
Lighting effects must not be connected to dimming-packs.
There is a power output connector and a power input plug on the rear panel. Connect one output with the
input of the next fixture until all fixtures are connected.
Please note:
A maximum of 8 LED DMS-2 RGBAW devices may be linked together.
After every 8 devices, the fixtures must have a renewed connection with the power mains.
OPERATION
The device has two operating modes. It can be operated via DIP switches in Stand Alone mode or it can be
run via a DMX controller in DMX-controlled mode.
After you connected the LED DMS-2 RGBAW to the mains, it starts running.
OPERATION VIA DIP SWITCHES
In DIP-switch operation, the LED DMS-2 RGBAW can be used without a controller. Disconnect the device
from the controller.