Accessory case
Prohibited action
Warning
*1 Depending on attached battery. The heaviest weight is
measured with BSL36B18 (sold separately).
Battery
Lights ;
The battery remaining power is over 75%.
Lights ;
The battery remaining power is 50%–75%.
Lights ;
The battery remaining power is 25%–50%.
Lights ;
The battery remaining power is less than 25%.
Blinks ;
The battery remaining power is nearly empty.
Recharge the battery soonest possible.
Blinks ;
Output suspended due to high temperature.
Remove the battery from the tool and allow it to
fully cool down.
Blinks ;
Output suspended due to failure or malfunction.
The problem may be the battery so please
contact your dealer.
STANDARD ACCESSORIES
In addition to the main unit (1 unit), the package contains
the accessories listed on page 99.
Standard accessories are subject to change without notice.
APPLICATIONS
○ Flush cutting and pocket cutting of various materials
○ Peeling of tiles, caulking, etc.
○ Polishing wood materials, etc.
SPECIFICATIONS
1. Power tool
The specifications of this machine are listed in the
Table on page 99.
NOTE
Due to HiKOKI's continuing program of research and
development, the specifications herein are subject to
change without prior notice.
2. Battery
Model
BSL1820M
Voltage
Battery capacity
18 V
2.0 Ah
CHARGING
Before using the power tool, charge the battery as follows.
<UC18YFSL>
1. Connect the charger's power cord to the
receptacle.
When connecting the plug of the charger to a
receptacle, the pilot lamp will blink in red. (See Table 1)
2. Insert the battery into the charger.
Firmly insert the battery into the charger as shown in
Fig. 4 (on page 2).
3. Charging
When inserting a battery in the charger, charging will
commence and the pilot lamp will light continuously in
red.
When the battery becomes fully recharged, the pilot
lamp will blink in red. (See Table 1)
(1) Pilot lamp indication
The indications of the pilot lamp will be as shown in
Table 1, according to the condition of the charger or the
rechargeable battery.
Table 1: Indications of the pilot lamp
ON/OFF at 0.5 sec. intervals
Lights continuously
Lights for 1 sec. at intervals of
0.5 sec.
ON/OFF at 0.1 sec. intervals
NOTE
*1 If the red lamp continues to blink even after the charger
has been attached, check to confirm that the battery
has been fully inserted.
*2 Battery overheated. Unable to charge.
Although charging will start once the battery has cooled
down even when left in situ, the best practice is to
remove the battery and allow it to cool down in a
shaded, well-ventilated location before charging.
*3 Malfunction in the battery or the charger
Fully insert the battery.
Check to confirm that no foreign matter is stuck to
the battery mount or terminals. If there are no
foreign objects, it is probable that the battery or
charger is malfunctioning. Take it to your authorized
Service Center.
○ If the pilot lamp does not blink in red even though the
charger cord is connected to the power, it indicates that
the protection circuit of the charger may be activated.
Remove the cord or plug from the power and then
connect it again after 5 minutes or so. If this does not
cause the pilot lamp to blink in red, please take the
charger to the HiKOKI Authorized Service Center.
○ When the battery charger has been continuously used,
the battery charger will be heated, thus constituting the
cause of the failures. Once the charging has been
completed, give 15 minutes rest until the next charging.
(2) Regarding the temperatures and charging time of the
battery. (See Table 2)
9
English
Before charging *
1
or
Charging complete
While charging
Overheat standby *
2
Charging impossible
*