Herunterladen Inhalt Inhalt Diese Seite drucken

Replacing The Power Cable; Cleaning, Maintenance And Ordering Of Spare Parts; Ordering Replacement Parts; Disposal And Recycling - EINHELL DHG 360 Originalbetriebsanleitung

Diesel-heißluftgenerator
Vorschau ausblenden Andere Handbücher für DHG 360:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

8. Replacing the power cable

Danger!
If the power cable for this equipment is damaged,
it must be replaced by the manufacturer or its
after-sales service or similarly trained personnel
to avoid danger.
9. Cleaning, maintenance and
ordering of spare parts
Danger!
Always pull out the mains power plug before star-
ting any cleaning work.
9.1 Cleaning
Keep all safety devices, air vents and the
motor housing free of dirt and dust as far as
possible. Wipe the equipment with a clean
cloth or blow it with compressed air at low
pressure.
We recommend that you clean the device
immediately each time you have finished
using it.
Clean the equipment regularly with a moist
cloth. Do not use cleaning agents or solvents;
these could attack the plastic parts of the
equipment. Ensure that no water can seep
into the device. The ingress of water into an
electric tool increases the risk of an electric
shock.
9.2 At the end of the season and before long
breaks in operation (Fig. 4)
Empty the fuel tank via the drain plug (9) on the
bottom of the tank by pulling the plug cover in
downwards direction. Collect the old oil in a con-
tainer and dispose of it in accordance with the
regulations in force.
If the drain plug is damaged, be sure to replace
it. Press the new plug into the tank drain hole and
close it with the plug cover (see Fig. 5).
Store the equipment and accessories out of
children's reach in a dark and dry place at above
freezing temperature. The ideal storage tempera-
ture is between 5 und 30 °C.
9.3 Servicing
Servicing work may be carried out only by spe-
cially trained personnel. Please contact Customer
Service.
Anl_DHG_360_SPK7.indb 26
Anl_DHG_360_SPK7.indb 26
GB

9.4 Ordering replacement parts:

Please provide the following information on all
orders for spare parts:
Equipment model/type
Equipment article number
Equipment ID number
Spare part number of the required spare part
For our latest prices and information please go to
www.isc-gmbh.info

10. Disposal and recycling

The equipment is supplied in packaging to pre-
vent it from being damaged in transit. The raw
materials in this packaging can be reused or
recycled.
The equipment and its accessories are made
of various types of material, such as metal and
plastic. Defective components must be disposed
of as special waste. Ask your dealer or your local
council.

11. Troubleshooting

If the equipment is operated properly you should
experience no problems with malfunctions or
faults. In the event of any malfunctions or faults,
please check the following before you contact
your customer services.
Fault
The fan motor does not start up, the LED is off .
Possible cause
a) Power failure.
b) The power cable or the power cable is dama-
ged.
c) The safety temperature limiter switches on.
d) Defective miniature fuse.
Remedy
a) Check the voltage, if necessary wait for re-
start.
b) Have repairs carried out by a specialized
company.
c) Establish the cause of the overheating. Go
not cover the air inlet/outlet channels.
Wait for at least 10 minutes until the equip-
ment has cooled down, then restart. If neces-
sary, contact Customer Service.
d) Replace the miniature fuse.