Herunterladen Diese Seite drucken

Purmo FLORES E Montage- Und Betriebsanleitung Seite 39

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

EXPERT SETTINGS
ACCESS
You access to expert settings in 5 steps.
From Auto, Comfort, Eco or Frost protection mode:
1
Information
display
auto
Press for 5
1
seconds
mode
Information
display
auto
prog
boost
OK
mode
SETTING SEQUENCE:
Anpassung des Umgebungstemperatursensors
AMBIENT TEMPERATURE SENSOR ADJUSTEMENT
Overview
Important:
This operation is reserved for professional
installers only; any wrong changes would result in control
anomalies.
In which case if the temperature measured (measured by
reliable thermometer) is different by at least 1°C or 2°C com-
pared to the setting temperature of the radiator.
The calibration adjusts the temperature measured by the
ambient temperature sensor to compensate for a deviation from
+ 5°C to - 5°C by intervals of 0.1°C.
Ambient temperature sensor adjustement
1- If the room temperature difference is negative, example:
Setting temperature (what you want) = 20°C.
Ambient temperature (what you read on a reliable
thermometer) = 18°C.
Difference measured = -2°C.
Important:
Before carrying out the calibration it is recom-
mended to wait for 4h after the setting temperature modifica-
tion to insure that the ambient temperature is stabilized.
To correct, then proceed as follows:
Sensor temperature = 24°C
(The measured temperature may be different due to the loca-
tion of the thermostat in the room).
2
prog
boost
Press briefly
twice
OK
4
Long and simultaneous 10
seconds press
Leistung einstellen
Information
displays
auto
prog
boost
1
OK
mode
Pro
5
= Expert settings
auto
prog
boost
Press briefly
OK
mode
Werkseinstellungen wiederherstellen
auto
mode
Decrease the temperature measured by the ambient tempera-
ture sensor by 2°C by pressing
In our example the measured temperature by the sensor goes
from 24°C to 22°C.
auto
mode
2- If the room temperature difference is positive, example:
Setting temperature (what you want) = 19°C.
Ambient temperature (what you read on a reliable
thermometer) = 21°C.
Difference measured = +2 °C.
3
auto
prog
boost
Press for 10
seconds
OK
mode
prog
boost
OK
.
prog
boost
OK
EN
39

Werbung

loading

Diese Anleitung auch für:

Flores c e