Exemption to an order coming from a pilot wire exter-
nal programmer
This feature allows you to modify temporarily the setting tempe-
rature until the next order sent by the central control unit or the
transition to 00:00.
Example:
1- The device is in Auto mode. The central control unit sent an
Eco order 15,5°C.
auto
mode
2- By pressing
or
, you can change temporarily the
desired temperature up to 18°C for example.
auto
mode
Note: The cursor corresponding to the operating mode, i.e Eco
mode in our example, is blinking during the duration of the
temporary deroga-tion.
3- his modification will be automatically cancelled at the
next order sent by the central control unit or the transition to
00:00.
auto
mode
INFORMATION ABOUT PRIORITIES BETWEEN
THE DIFFERENT MODES
Principe
In Comfort, Eco and Frost protection modes, only orders of the
open window sensor will be considered.
In Auto mode, the device can receive different orders coming from :
- 7 day and daily programming integrated (Comfort or Eco orders);
- 6-order pilot wire, if connected to central control unit;
- Open window detector.
In general, it is the lowest received order which prevails except
when the pilot wire is connected to an energy management
system, in this case the orders of the pilot wire take priority.
In case of programmed Boost, the Boost activation will take pre-
cedence over others orders received except when the standby
(stop) order is pre-sent on the pilot wire, the device will switch
off and the Boost will be not activated.
prog
boost
3
OK
prog
boost
3
OK
prog
boost
3
OK
Examples
7 day and daily programming
Pilot wire 6 orders
Eco
7 day and daily programming
Pilot wire 6 orders
Open window detector
Standby mode
= Comfort
= Eco
auto
prog
3
= Eco
mode
= Stop (standby mode)
= Frost protection
auto
prog