Herunterladen Inhalt Inhalt Diese Seite drucken

Cleaning And Maintenance - eta FENIX Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 48
EN
ON / OFF button (A1)
- press and hold the button to switch the vacuum cleaner on
- release the button to switch the vacuum cleaner off
Button "
" - suction power adjustment (B1)
- press short the button to increase/reduce the suction power (suction power is indicated by
lighting LEDs B2 (MIN / ECO / MAX).
- MIN /
= low- mode,
- ECO /
= economic mode,
- MAX /
= high mode.
Notes: The vacuum cleaner is set to ECO suction power when switched on.
Floor nozzle D have electronic protection against rotation brush blocking. If the rotation
brush has been blocked during operation, observe the following instructions.
– If the floor nozzle rotation brush D has been blocked, LEDs D2 go off and the brush
stops rotating. Switch off the device and remove the cause, then the device can be
switched on again.
Full dust container and HEPA filter signaling
If the red light on the A2 control panel lights up permanently, the filter system must be
cleaned even if the container is not yet full. Do not take into account the occasional
illumination of the indicator light during vacuuming. If the suction opening/airways become
blocked, the overload protection switches off the motor (valid when the suction power is set
to MIN). If this situation occurs, switch off the vacuum cleaner and remove the cause of the
blockage and then you can switch the vacuum cleaner on again.
V. CLEANING AND MAINTENANCE
DUST CONTAINER (A4)
If you find out that the suction performance of the vacuum cleaner A is reduced, make sure
that the dust container is not full and if necessary, empty it (follow the procedure indicated
in Fig. 6). Put the container above a dust bit and press button A6; thus you will lift off bottom
and throw the dust in common municipal waste. Snap the bottom shut to secure it in the
opposite direction.
REPLACING THE HEPA FILTER (A7)
When removing the HEPA filter, proceed according to Fig. 7. Insert the new/clean HEPA
filter into the dust container a reverse order.
– For hygienic purposes we recommend that you empty the container and clean the
HEPA filter after each use.
– Maximum suction power can be achieved when the HEPA filter are clean and the
dustbag is empty.
– Every time you empty the dust container, we recommend that you also clean the HEPA filter.
– When you are vacuuming very fine dust, the HEPA filter pores might get clogged. This
reduces the air flow and reduces the suction power. In such a case, the filter and the
separator need to be cleaned even though the container is not full yet.
Caution
Notes
28
/ 56

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

X233

Inhaltsverzeichnis