Herunterladen Diese Seite drucken

Balluff BFD 3SAP-19N000-U01-LA2-C S04 Serie Montageanleitung Seite 6

Ultraschall-sensoren

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Sensortyp
Ultrasonic sensors
Dimensions
38.9
BFD 3SAP-...S75
BFD 3SAP-...S04
48.4
BFD 3SAP-...000
Electrical connection
Depending on the connection variant, the electrical
connection is either a fixed connection via a cable or a
plug connection.
Type
Connector
BFD 3SAP-...S04
2
BFD 3SAP-...S75
2
1
BFD 3SAP-...000
M 8-4 (Class A)
Pin
Wire color
Signal
1
BN
L+ (Operating voltage +,
SIO 10...30 V, IO-Link 18...30 V)
2
WT
I/Q (Digital input / digital output /
analog output)
3
BU
L− (Operating voltage −)
4
BK
C/Q (IO-Link communication /
digital output in SIO mode)
2
english
L
LED
Pin assignment
1
S04 (top view of
plug)
4
3
Pin assignment
4
S75 (top view of
plug)
3
No plug
30.9
19.4
Measuring cavity
10.9
9.5
Measurement range
10
27
Vent hole
L depends on type (see type code in the user's guide)
Shielding and cable routing
Cable routing
Defined ground!
The sensor and the control cabinet must be on
the same ground potential.
Route all cables between sensor, controller and power
supply so that they are not under tension. In order to avoid
electromagnetic interference, ensure sufficient distance to
cables carrying a heavy current and cables with high-
frequency voltage signals (e.g. of frequency converters).
Bending radius for fixed cable
The bending radius for fixed cable routing must be at least
12 mm.
Cable length
The maximum length of the cable to the IO-Link master is
20 m.
Longer cables can also be used for the analog output,
provided that the design, shielding and routing ensure that
external interference is prevented.

Werbung