The machine has been built according to the latest technology
and recognised safety rules. However, there is still a chance of
residual risks whilst working.
Endangering health through noise.
Endangering health through electricity, when using improperly
connecting cables.
1.
Speed adjustment
2.
Locking mechanism for on switch
3.
Handle
4.
Additional handle
5.
Suction adjustment
6.
Main switch
7.
Dust extractor
8.
Grinding plate
Main switch and speed adjustment (Fig. 1+2)
This device is equipped with a locking mechanism for the on switch so
that the device remains on after it has been switched on.
• Switching the device on using the „On" button: Actuate the main
switch (1) to start the electric tool
• Leaving the device switched on using the „On" button: For conti-
nuous operation, actuate the locking mechanism for the on switch (2)
so that device continues to operate.
• Switching the device off using the „Off" button: To switch the
device off, only briefly press the main switch (1) and release it imme-
diately.
• Adjusting the speed: You can control the speed of the grinding
plate by adjusting the speed control (3).
GB
Inserting and changing the sand paper (Fig. 3+4)
Note: Before inserting or removing the sand paper, make sure to switch
off the device and disconnect it from the power supply.
• To replace the sand paper (1), place the device on the floor. Take
the sand paper (1) and secure it on the grinding plate (2). The sand
paper (1) automatically connects to the grinding plate (2). Make sure
that the holes of the grinding plate (2) align with the holes of the sand
paper (1).
The installed electronic motor is connected and operational. The con-
nection complies with relevant VDE and DIN stipulations.
The customer's mains connection as well as extension leads used must
comply with these provisions.
Hazardous electronic connections
Insulation damage often occurs on electric connections.
Causes include:
• Pressure marks when connections are guided through windows and
doors
• Kinks due to inappropriate attachment or guidance of the connection
• Cuts when the connection is run over
• Insulation damage when being pulled out of the wall socket
• Tears from ageing insulation
Such hazardous electric connections must not be used and are dange-
rous to life due to the insulation damage.
Regularly check electric connections for damage. Make sure the
connection is not connected to the mains when checking. Electric
connections must comply with relevant VDE and DIN stipulations. Only
use connections marked H 07 RN. Printing the type designation on the
connection is the law.
Residual risks m
Additionally, despite all the safety provisions, residual risks can
occur which are not obvious.
Residual risks can be minimised by complying with the "Safety
notices", the "Intended use" as well as operating instructions
overall.
Equipment fig. A
9.
Sand paper 6 units (grain: 80, 100, 120, 150, 180, 240)
10. Flexible suction hose
11. Dust bag
12. Carrying strap
13. Replacement carbon brushes, 2 brushes
14. Screwdriver
15. Allen key
16. Connection adapter
Commissioning
Connection set for the dust extractor
The connection piece for the dust extractor is used to connect the
device with the fabric bag. This minimises the level of dust for the
operator.
Connect the device to the suction hose (Fig. 5.1, 5.2, 5.3)
• Plug the adapter connector (1) on the vacuum cleaner connection (2)
of the machine and turn it to lock it.
• Insert the dust hose (3) into the dust extractor (4).
Connect the dust bag to the suction hose (Fig. 6.1, 6.2, 6.3, 6.4)
• Installation instructions: Insert the hose (1) into the connection piece
of the dust bag (2). Make sure that the spigot locks into place in the
connection piece of the dust bag to securely connect the hose (1)
with the dust bag (2). (Fig. 6.1, 6.2)
• Removal: Press the locked connection piece of the hose (1) together
using a screwdriver and remove the hose (1). (Fig. 6.3, 6.4)
Adjusting the suction power (Fig.7)
• Turn the suction adjustment control until the desired suction power is
achieved.
Electrical connection m
AC motor
• The power voltage has to be 230 Volt – 50 Hz.
• Extension leads up to 25 m in length must have a cross section of
1.5 mm2, at more than 25 m length, it has to be at least 2.5 mm2.
• The mains connection is protected against short circuit with a 16A
slow fuse.
Connections and repairs to the electrical equipment may only be
carried out by a trained electrician.
If there are any questions, please provide the following data:
• Motor's type of power
• Data from the machine's type plate
When sending back the motor, always send the entire motor unit with
switch.
Follow the safety notices!