Important: According to the current local and national regulations, it is mandatory to add a switch (or other element to
disconnect the system) to the external supply wiring so that a constant separation between poles is guaranteed. The system
will restart automatically if the supply is eventually turned off.
Remember: Once all the connections are made, make sure you replace the cover properly.
Reset the system
If you want to return to factory values, press and hold SW1
LEDS to go back to their normal state before starting with the initial configuration process.
Changing batteries
To replace the battery, separate the thermostat from its support and
replace the battery (CR2450).
Important: We recommend using of top-brand batteries. Using low-
quality batteries may reduce the duration of use
Remember to deposit the old battery into an appropriate recycling point.
Note: Do not forget to remove the security system before taking away the
thermostat from the wall.
ASSEMBLY AND CONNECTION EVALUATION
Check the following aspects:
-
The state of the LEDs of the main control board and the rest of control elements. Check the self-diagnose section.
-
Wired and wireless thermostats power supply.
INITIAL CONFIGURATION
IMPORTANT: In order to associate wireless thermostats, you must open before the wireless module. To do
that, press on SW1. The LED D19 will remain steady red. Once open, you have 15 minutes to make the
association. If that period of time expires, start the process over again. Remember not to open more than
one module at the same time, it may alter the process.
You can also open the channel association radio through the Blueface and Think (see section System
parameters).
until LED D19 stops flashing. Wait for the
.