2.1Precautions

WARNING indicates a hazardous situation which, if not avoided, could result in death or
serious injury.
NOTICE is used to address practices not related to personal injury.
To maintain the safety and full functionality of the R07A, it is important that instructions
set forth in this manual are strictly followed.
Ensure compliance with environmental conditions (during transport, storage and
operating). If the device is moved from a cold location to a warmer one or vice versa, there
will be a risk of condensation build up. If condensation occurs the device must be allowed
to achieve normal temperature before it is turned on.
To avoid damage to the device and leakage from the batteries, batteries should be
removed whilst the device is being stored.
R07A does not have specific ingress protection. Care should be taken to avoid liquid
ingress. Immersion of the device may result in serious damage.
Although the instrument fulfils the relevant EMC requirements, precautions should be
taken to avoid unnecessary exposure to strong electro-magnetic fields, e.g. from mobile
phones, microwaves, radiotherapy devices, etc.; this may induce malfunctions in their
performance. If the device is used adjacent to other equipment it must be observed that
no mutual disturbance appears.
The R07A is intended to be powered from batteries or from a medical CE power supply
offered as an option. Using other supplies is not allowed. When used, position it so that
the power plug can be easily disconnected.
The device should be placed at least 20 cm from a heat source.
Be sure to use only stimulation levels, which will be acceptable for the patient.
The transducers supplied with the R07A are calibrated to this device (see DHR documents
supplied with the device); exchange of transducers will require a recalibration.
Sudden impacts or drops may cause damage to the device, which may affect its
performance and safety. Repairs should only be undertaken by a qualified technician.
If the R07A is connected to other devices with their own power source, the system conforms
to EN 60601-1 must be checked under the responsibility of the installer; in the event that
isolation devices are used to achieve such conformity, these must comply with EN 60601-1.
Any person who connects external equipment to the device connectors has formed a sys-
tem and is therefore responsible for the system to comply with the requirements of IEC
60601-1.
If in doubt, contact your RESONANCE technician or local distributor for help.