Herunterladen Diese Seite drucken

BWT Bolero RF Serie Einbau- Und Bedienungsanleitung Seite 30

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

EN
0 0 0
Σ m
> 400 mm
30
3
> 20 mm
> 1 m
I.
III.
6
Installation
Install filter according to its nominal width in cold
water pipes of the same dimensions and before
the equipment to be protected. Install stop valves
before and after the filter.
Route the waste water connection (see page 3,
Fig. 3) with tube to the sewage channel or provide
a collection basin (capacity approx. 10 l).
Please note: A ccording to DIN EN 1717 the flushing
Installation 3/4" – 1 1/4" only
Install connecting module in the direction of flow in
the horizontal or vertical cold water pipe (observe
direction of flow arrow).
I.
Turn the retaining ring to the left until it stops.
II. Push the unit's catches into the recesses
II.
III. Rotate the unit by 45º clockwise until it stops.
IV. Pull the retaining ring with both hands towards
the unit until it locks into place. The unit is now
protected against accidental twisting.
To loosen the filter, press the retaining ring towards
the connecting module.
VI.
water hose must be installed at a
minimum distance of 20 mm to the
highest possible waste water level
(free discharge).

Werbung