CAUTION:
▲Do not install the air conditioner at any place where there is danger of flammable gas leakage.In the
event of a gas leakage, build-up of gas near the air conditioner may cause a fire to break out.
▲Tighten the flare nut according to the specified method such as with a torque wrench.If the flare nut
is too tight, it may crack after prolonged use, causing refrigerant leakage.
▲Take adequate steps to prevent the outdoor unit being used as a shelter by small animals.Small
animals making contact with electrical parts can cause malfunctions, smoke or fire.
▲Please instruct the customer to keep the area around the unit clean
▲The temperature of refrigerant circuit will be high, please keep the inter-unit wire away from copper
pipes that not thermally insulated.
▲Only qualified personnel can handle, fill, purge and dispose of the refrigerant.
▲If the unit is installed in coastal areas or other regions with sulfate gas of salty atmosphere,
corrosion will occur and the unit service life will be shortened
EUROPEAN REGULATIONS CONFORMITY
FOR THE MODELS
Climate:T1 Voltage:230V
CE
All the products are in conformity with the following European
provision:
2014/53/EU (RED) 2014/517/EU (F-GAS) 2010/30/EU (ENERGY)
2009/125/EC (ENERGY) 2006/1907/EC (REACH)
RoHS
The products are fulfilled with the requirements in the directive
2011/65/EU of the European parliament and of council on the
Restriction of the use of Certain Hazardous Substances in
Electrical and Electronic Equipment (EU RoHS Directive)
WEEE
In accordance with the directive 2012/19/EU of the European
parliament, herewith we inform the consumer about the dis-posal
requirements of the electrical and electronic products.
DISPOSAL REQUIREMENTS:
Your air conditioning product is marked with this symbol.
This means that electrical and electronic products shall
not be mixed with unsorted household waste. Do not
try to dismantle the system yourself : the dismantling of
the airconditioning system,treatment of the refrigerant,
of oil and of other part must be done by a qualified installer
in accordance with relevant local and national legislation. Air
conditioners must be treated at a specialized treatment facility for
reuse, recycling and recovery. By ensuring this product is disposed
of correctly, you will help to prevent potential negative cons-
equences for the environment and humen health. Please contact
the installer or local authority for more information. Battery must be
removed from the remote controller and dis-posed of separately in
accordance with relevant local and nationl legislation.
Wi-Fi
-Wireless maximum transmit power (20dBm)
-Wireless operating frequency range (2400~2483.5MHz)
IMPORTANT INFORMATION REGARDING
THE REFRIGERANT USED
Contains fluorinated greenhouse
gases covered by the Kyoto Protocol
R32
2
1
F
E
This product contains fluorinated greenhouse gases covered by
the Kyoto Protocol. Do not vent into the atmosphere. Refrigerant
type: R32
GWP* value=675
GWP=global warming potential
Please fill in with indelible ink,
•1
the factory refrigerant charge of the product
•2
the additional refrigerant amount charged in the field and
•1+2 the total refrigerant charge
on the refrigerant charge label supplied with the product. The filled
out label must be adhered in the proximity of the product charging
port (e.g. onto the inside of the stop value cover).
A contains fluorinated greenhouse gases covered by the Kyoto
Protocol
B factory refrigerant charge of the product: see unit name plate
C additional refrigerant amount charged in the field
D total refrigerant charge
E outdoor unit
F refrigerant cylinder and manifold for charging
The values of CO2 equivalent are shown in Table 1
A
1=
kg
B
2=
kg
C
1+2=
kg
D
3 3