Herunterladen Inhalt Inhalt Diese Seite drucken
Vorschau ausblenden Andere Handbücher für PW27P:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Mechanical installation
4.2

Mounting

Attach the load cells at the mounting holes and apply load to the other end.
The scope of supply includes 2 gaskets for sealing the gap surfaces on the
face against microbiological contamination. The screws and tightening torques
to be used are given in the following table:
Version
Standard
Rustless
1)
Recommended value for the specified property class. Please comply with the screw
manufacturer's instructions with regard to screw dimensions.
Dimensions in mm (1 mm = 0.03937 inches)
Load
application/
platform center
Installation: 2 x M6 tightening torque
10 Nm, max. thread reach 14 mm
Fig. 4.1
Load application and installation
Important
Load must not be applied to the side where the cable connection is located, as
this would cause a force shunt.
10
Thread
Max. thread
reach
M6
14 mm
M6
14 mm
2 O‐ring seals
(in scope of supply)
130
A03631_02_Y00_00 HBM: public
Min. property
class
8.8
A2-70 or A4-70
Installation: 2 x M6 tightening torque 10 Nm
max. thread reach 14 mm
∅14
Connect
or plug
Optional centering:
2 centering bores on both
sides, on the face
Tightening
1)
torque
10 N⋅m
10 N⋅m
30°
4.09±0.02
27±0.02
PW27P

Werbung