Herunterladen Inhalt Inhalt Diese Seite drucken

Conditions At The Site Of Installation; Ambient Pressure; Special Information; Mounting Instructions - HBM C2 Montageanleitung

Vorschau ausblenden Andere Handbücher für C2:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

20
1

Conditions at the site of installation

1.1 Ambient pressure

The ambient pressure for transducers may be between 0 and 5 bar. Please
note that pressure changes may shift the zero output signal.
Max. capacity
kg
t
Change of
zero point
[%/10 mbar]

1.2 Special information

The C2 transducers are produced entirely from non-rusting materials. The
user must test for resistance to aggressive environmental conditions in each
individual case.
2

Mounting instructions

• Handle the transducer carefully.
• The transducer seating must be horizontal, even and, together with the
transducer mounting surface, it must be absolutely clean.
• Dust, dirt and other foreign matter must not be allowed to collect so that the
deflection of the transducer is impaired, leading to possible erroneous mea-
surements.
• Do not overload the transducers (e.g. by unevenly distributed loads); if nec-
essary, provide overload protection (e.g. supports).
• Each transducer should be shunted by a stranded copper cable (approx.
2
16 mm
) during or immediately after installation, in order to prevent any
welding or lightning currents flowing through the transducer.
HBM
50
100
200
0.065 0.032 0.016 0.006 0.003 0.006 0.003 0.002 0.001 <0.001
500
1
2
5
10
20
A1683-1.0 de/en/fr
C2
50

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis