Information about Safety

3.1 Safety Spacing in the Heat-radiation Area

Flammable materials in the heat-radiation area of the fire door can be ignited. To avoid fires, keep the
safety spacing of X [cm] between combustible materials and the fire door of your system.
Fireplace
SOE 58x46x36
SOE 69x52
SOE 69x52 Tunnel
*No data from the test report. Country-specific values have priority. Data according to TROL (DE) and
STP (CH)
3.2 Air Grille
Air grilles can be fitted in the casing depending on the type and function of your system. The
convention air must be freely able to circulate through this air grille. Ensure that the air grilles are not
closed or covered by any objects.
3.3 Precoat
Combustible floors must be protected around the fire doors by a non-combustible precoat. The precoat
on your fireplace may not be removed.
3.4 Fire Door
Your fire door is self-closing or not self-closing depending on the design. Self-closing fire doors have a
safety function combined with other combustion units that are connected to the same chimney.
No manipulation or changes to the fire door are permitted. Have the defective fire doors and gaskets
repaired by the specialist installer straight away.

3.5 Combustion Air

Depending on the type and function of your system the combustion air is fed into the system from the
installation room (dependent upon ambient air) or from the outside (separated from ambient air).
Ensure that sufficient ambient air can always flow in when several systems in a composite heating
system are working simultaneously. Appliances that extract ambient air (extractor hoods, ventilation
systems, central dust extraction units etc.) may not affect the operating safety of your system.
System dependent upon ambient air
Ensure that sufficient fresh air is always able to flow into the installation room.
System separate from ambient air
Ensure that the fresh air vent on the external facade or in the basement of the building is neither
closed nor covered by any objects.
Instruction Manual
X [cm]
90
80*
80*
41