Inductive sensors
6
System Functions (continued)
6.6

LED Meaning and Configuration

6.6.1
Description
Only the signal with the highest priority is displayed. The
signals are listed in descending priority.
Balluff Standard
Name
Device Discovery
Short Circuit Pin 2 / Pin 4
Teach-in No Object
Failure
Teach-in
Maintenance Required
Overload
Bad Signal Quality
Out of Specification
Function Display
Communication
Ready
Tab. 6-17: LED meaning and configuration – Balluff Standard
88
english
Signal
Blue, flashing, 3 Hz
Red, flashing, 3 Hz
Red, flashing, 1 Hz
Red, static
Red, static
Blue, static
Orange, flashing, 3 Hz
Orange, flashing, 1 Hz
Yellow, flashing, 3 Hz
Yellow, static
Green alternating with LED
off at ratio of 10:1, 1 s
period
Static green
Meaning
The Device Discovery can be activated via a system
command to find the device again.
Short circuit at pin 2 or pin 4
The sensor is in Teach-In mode and no object is visible.
Teaching is not possible.
General error
The device is currently in teach-in mode
Maintenance must be performed.
Overload on pin 2 / pin 4 has been detected.
Poor signal quality, the signal quality is below the
configured warning threshold.
The device is operated outside of specifications. A
reliable measurement signal can no longer be ensured.
The object was detected / switching point is active
IO-Link communication is active. The device is ready.
The device is ready.