Herunterladen Inhalt Inhalt Diese Seite drucken

Storage Usage Monitoring - Balluff BES M12EG1-L01C80F-S04G-L04 Konfigurationsanleitung

Vorschau ausblenden Andere Handbücher für BES M12EG1-L01C80F-S04G-L04:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

BES M12EH1-L01C40B-S04G-L04 / BES M12EG1-L01C80F-S04G-L04 /
BES M18EH1-L01C80B-S04G-L04 / BES M18EH1-L01C12F-S04G-L04
Inductive sensors
5
Secondary Device Functions (continued)
5.14.4 System Commands
For an overview of all System Commands, see section 3.5
on page 21.
5.14.5 Events
Event Code
Event Type
0x8D12 (36114)
Warning
Tab. 5-65: Humidity detection – Events
5.15

Storage Usage Monitoring

5.15.1 Description
All variable data is stored in a permanent memory on the
device. The data is stored in various segments for different
access and usage purposes.
Because the number of write cycles in the permanent
memory is limited, the number in each segment is
monitored by a counter.
All data segments are protected with a CRC32 checksum.
5.15.2 Events
Event Code
Event Type
0x8D22 (36130)
Warning
0x8D23 (36131)
Error
0x8D24 (36132)
Warning
Tab. 5-66: Storage usage monitoring – Events
www.balluff.com
Description
The defined threshold of the device-internal
humidity was exceeded.
► Check installation and ambient conditions.
Description
Warning limit for write cycles reached –
maintenance monitoring no longer guaranteed – for
information purposes only.
Write cycle limit reached – saving no longer
ensured – replacement recommended.
Parameter write error – An error occurred while
writing the data – for information purposes only.
Device Status
1 – Maintenance-Required
Device Status
0 – Device is operating properly.
1 – Maintenance-Required
0 – Device is operating properly.
english