Secondary Device Functions (continued)
Speed Monitoring Startup Delay
With Startup Delay, the time for the startup delay can be
set. The startup delay begins after the supply voltage is
switched on. During the startup delay, speed monitoring
has no function. Speed monitoring starts after the startup
delay has elapsed. The value represents the time in
seconds. The value range is between 0x00 (0) and 0xFF
(255). A value of 0x00 (0) represents no start delay.
Speed Monitoring State
With Speed Monitoring State, the current status can be
read.
Value
Meaning
0x00 (0)
Idle
0x01 (1)
Too low
0x02 (2)
OK
0x04 (4)
Too high
0x08 (8)
Startup
Delay
0xFF (255)
Deactivated
Tab. 5-12: Signal Speed Monitoring – Speed Monitoring State
Speed Monitoring Value
With Speed Monitoring Value, the current speed value can
be read.
5.3.5
System Commands
Command
Device Action
Value
0x81 (129)
Application Reset – Resets writable
parameters to the default value.
0x82 (130)
Reset Factory Settings – Resets writable
parameters to the default value.
0xAA (170)
Signal Speed Monitoring Reset – Resets
the speed value and flags.
Tab. 5-13: Signal Speed Monitoring – System Commands
For an overview of all System Commands, see section 3.5
on page 21.
46
english
Description
No speed value yet available
Speed value is less than the
lower threshold
Speed value is in the suitable
range
Speed value is greater than
the upper threshold
Startup delay currently
running
Feature is deactivated