Herunterladen Inhalt Inhalt Diese Seite drucken

Balluff BES M12EG1-L01C80F-S04G-L04 Konfigurationsanleitung Seite 134

Vorschau ausblenden Andere Handbücher für BES M12EG1-L01C80F-S04G-L04:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

BES M12EH1-L01C40B-S04G-L04 / BES M12EG1-L01C80F-S04G-L04 /
BES M18EH1-L01C80B-S04G-L04 / BES M18EH1-L01C12F-S04G-L04
Inductive sensors
4
Primary Device Functions (continued)
Fine Adjust Config
This ISDU is used for configuring the Fine Adjustment. The
switching channel that is to be adjusted to and, depending
on the selected switching mode, the adjustment mode can
be selected.
Value
Meaning
Channel
0x00 (0)
Default
0x01 (1)
SSC1
0x02 (2)
SSC2
Mode
0x00 (0)
SP1 + SP2
0x01 (1)
SP1
0x02 (2)
SP2
Tab. 4-19: Switching profiles – Fine Adjust Config
Transducer Signal
See Transducer Signal on page 33.
36
english
Description
Default Channel
LSSC Channel 1
LSSC Channel 2
SP1 and SP2 or SP1 and
hysteresis are adjusted.
Setpoint 1 is adjusted
(only in Two Point or
Window Mode).
Setpoint 2 is adjusted
(only in Two Point or
Window Mode).
4.3.6
System Commands
Command Value Device Action
0x40 (64)
Teach Apply – Calculates the
switching point for SP1, SP2.
0x41 (65)
Teach SP1 (ADSS: Teach SP) –
Determines teach point 1 for
setpoint 1 and calculates the
switching point.
0x42 (66)
Teach SP2 – Determines teach
point 1 for setpoint 2 and calculates
the switching point
0x43 (67)
Teach SP1 TP1 (ADSS: Teach TP1)
– Determines teach point 1 for
setpoint 1
0x44 (68)
Teach SP1 TP2 (ADSS: Teach TP2)
– Determines teach point 2 for
setpoint 1
0x45 (69)
Teach SP2 TP1 – Determines teach
point 1 for setpoint 2
0x46 (70)
Teach SP2 TP2 – Determines teach
point 2 for setpoint 2
0x47 (71)
Teach SP1 Start (ADSS: Teach SP
Start) – Starts dynamic teach-in for
setpoint 1
0x48 (72)
Teach SP1 Stop (ADSS: Teach SP
Stop) – Stops dynamic teach-in for
setpoint 1 and calculates the
switching point.
0x49 (73)
Teach SP2 Start – Starts dynamic
teach-in for setpoint 2
0x4A (74)
Teach SP2 Stop – Stops dynamic
teach-in for setpoint 2 and
calculates the switching point
0x4E (78)
Teach Reset – Any active teach-in
process is interrupted, all
temporarily stored values are reset.
0x4F (79)
Teach Cancel – Any active teach-in
process is interrupted.
0xB1 (177)
Fine Adjust near – Adjusts the
switching point one step closer to
the sensor.
0xB2 (178)
Fine Adjust far – Adjusts the
switching point one step further
from the sensor.
Not available for AdSS. Available for LSSC if the currently set mode
1)
supports 2 setpoints.
Tab. 4-20: Switching profiles – System Commands
For an overview of all System Commands, see section 3.5
on page 21.
1)
1)
1)
1)