BES M12EH1-L01C40B-S04G-L04 / BES M12EG1-L01C80F-S04G-L04 /
BES M18EH1-L01C80B-S04G-L04 / BES M18EH1-L01C12F-S04G-L04
Inductive sensors
3
Overview of IO-Link Data and Functions (continued)
Event Code
Event Type
0x8D20
Warning
(36128)
0x8D22
Warning
(36130)
0x8D23
Error
(36131)
0x8D24
Warning
(36132)
0x8D25
Error
(36133)
0x8DC0
Notification
(36288)
Tab. 3-8:
Events – Overview
www.balluff.com
Description
Device temperature lower warning – The set lower
temperature warning threshold is below the minimum
value.
Warning limit for write cycles reached – maintenance
monitoring no longer guaranteed – for information
purposes only.
Write cycle limit reached – saving no longer ensured
– replacement recommended.
Parameter write error – for information purposes
only.
Parameters not consistent – basic settings are used,
service required. Parameterization processes and
resets can no longer be performed.
Teach-in Timeout – The current teach-in process
took too long and was interrupted.
Device Status
0 – Device is operating properly.
0 – Device is operating properly.
1 – Maintenance-Required
0 – Device is operating properly.
4 – Failure
0 – Device is operating properly.
english
23