Herunterladen Inhalt Inhalt Diese Seite drucken

Panasonic AW-E750 Handbuch Seite 40

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Other Set Display
5
1. Contrast Adjustment
[Contrast (Gamma): LOW, MID, HIGH]
The contrast can be adjusted to any of three levels.
2. Electronic Shutter Setting
[Shutter Speed: OFF, 1/120 to 1/10 000, S/Scan, Auto ND]
OFF: Electronic shutter is turned off.
1/120, 1/250, 1/500, 1/1 000, 1/2 000, 1/4 000, 1/10 000:
Electronic shutter operates at one of these
speeds as selected.
S/Scan (Synchro Scan): Electronic shutter operates
at the speed set with the electronic shutter syn-
chro-scan setting (5-1).
Auto ND: Electronic shutter is controlled to automati-
cally adjust the luminance. (ELC)
Notes
• In case of using the RCU (RCB), none of the
shutter speeds − 1/250, 1/2 000, 1/4 000, and
1/10 000 can be selected.
• In case of using the hybrid control panel, only
OFF, 1/120, or Auto ND (ELC) can be selected.
• If the lens iris switch is at M (Manual) when oper-
ating the camera alone or when the iris switch on
the RCU (RCB) is at AUTO, Auto ND may not
function. Set the lens iris switch to A (Auto).
• Flickering may increase at Auto ND under fluo-
rescent lights.
• Auto ND is automatically selected if Auto ND
(ELC) setting is set to ON.
3. Electronic Shutter Synchro Scan Setting
[Synchro Scan: 50.24Hz to 15.63kHz]
This setting is possible only when Electronic Shutter
setting (5-2) is at S/Scan.
Horizontal bar noise can be reduced by synchro-
scan adjustment in shooting workstation scenes, for
example.
For luminance settings at each shutter speed and
synchro-scan shutter speed, refer to the table
below.
Shutter Speed
OFF
1/120
1/250
1/500
1/1 000
1/2 000
1/4 000
1/10 000
4. CCD Read Out Mode Setting
[V Resolution: Normal, Fine]
Normal: Normal image. (CCD storage will be by field
storage.)
Fine: Vertical resolution increases. (Vertical resolu-
tion is raised without increasing residual images
by frame storage and Electronic shutter.)
Normal is recommended for general use be-
cause sensitivity will decrease at the Fine setting.
-39 (E)-
Synchro-scan
Required luminance ratio
-
1
120.2 Hz
2
250.0 Hz
4
492.2 Hz
8
984.4 Hz
16
1.969 kHz
32
3.938 kHz
64
7.875 kHz
160

Werbung