Notes
• Only 0 dB, 9 dB, or 18 dB can be selected in
case of using the RCU (RCB).
• 0 dB when the manual GAIN switch on the hybrid
control panel is at LOW, 9 dB when it is at MID, or
18 dB when it is at HIGH.
Manual GAIN Switch
Hybrid Control Panel
8. Digital Gain Up Setting
[Digital Gain Up: 0dB, 6dB, 12dB, 18dB, 24dB, 30dB]
This can be set only when "OFF" has been selected
as the auto gain up setting (1-5).
0 dB: Under normal circumstances, this setting is
used.
6 dB to 30 dB: Use this setting while shooting dark
scenes if it is not possible to achieve a satisfacto-
ry video output even when the lens diaphragm is
opened and "Night Eye" is selected as the manu-
al gain up setting (1-7).
9. CCD Storage Time Setting
[Charge Time: Auto, OFF, 1/25s, 1/12s, 1/6s, 1/3s,
1/2s, 1s, 2s]
This is used to set the CCD storage time.
Auto: ALC is performed followed by AGC and then
by the data storage, and the camera automatical-
ly adjusts the light quantity.
If "ON" is selected as the auto ND (ELC) setting
(1-4), ELC is performed followed by ALC, AGC
and then by the data storage in this order, and
the light quantity is automatically adjusted.
The electronic shutter setting (5-2) cannot be
changed.
OFF: Under normal circumstances, this setting is
used.
1/25s to 2s: Use this setting if it is not possible to
achieve a satisfactory video output even when
the gain up setting is used.
The auto ND (ELC) setting (1-4) and electronic
shutter setting (5-2) go "OFF" and cannot be
changed.
If the images (CCD read out (mode) setting
(5-4)) have been set to "Fine", 1/12s to 2s is
selected as the storage time setting, and the
sensitivity is set to about one-half of that
obtained with when they have been set to
"Normal".
-35 (E)-