8.2
Capacity of the generating set
Before connecting and operating the unit, calculate the electrical power required by the units to be used (in watts)*. To ensure
optimal operation, the total wattage of all equipment used at the same time must be:
-
greater than 60% of the rated load for the unit (risk of insufficient load);
-
less than the rated load for the unit during continuous operation (risk of overload).
If the unit is run under or over its rated load frequently or for long periods of time, it can start to wear very quickly. Damage caused
in this way will not be covered by the warranty.
*
This load is usually indicated in the technical specifications or on the manufacturer's plate for the equipment. Some equipment requires a higher
load when starting. This minimum required power must not exceed the unit's maximum power
8.3

Generating set identification

The identification plate for the unit (example shown below) is affixed inside one of the skirts or on the chassis.
(C)
(B)
Serial numbers will be required when requesting troubleshooting advice or spare parts. For your records, please enter the unit and
engine serial numbers below.
Unit serial number:
....../.............. - ........................... - .........
8.4
Specifications
Model
Maximum power
Rated power
Acoustic pressure at 1 m
Acoustic measurement uncertainty
Engine type
Maintenance kit
Recommended fuel
Fuel tank capacity
Recommended oil
Oil sump capacity
Oil cut-out*
Direct current
Alternating current
Circuit breaker(s)**
Socket type
Battery
Dimensions l x w x h
Weight (without fuel)
o: standard
*Oil cut-out: If there is no oil in the engine sump or if the oil pressure is low, the oil cut-out mechanism automatically stops the engine to prevent any
damage. If this occurs, check the engine oil level and top it up if necessary before looking for any other cause of the problem.
**Circuit breaker: The set's electrical circuit is protected by one or more magnetothermal, differential or thermal cut-out switches. In the event of an
overload and/or short circuit, the supply of electrical energy may be cut.
If necessary, replace the circuit breakers in the generating set with circuit breakers with identical nominal ratings and specifications.
8.5
Recommended fuel quality
Using fuel which does not comply with the following specifications risks causing irreversible damage not covered under the
warranty:
-
Cleanliness and quality: ensure that the diesel used does not contain water, that it is new and clean (not out of date or
contaminated).
-
Specifications: ASTM D975 - 1D or 2D, EN590 or equivalent.
-
Outdoor temperature below 0°C: use a special fuel (for more information, please contact one of our agents).
However, it is strongly recommended that the same type of fuel is used throughout the complete service life of the unit. If the unit is
used infrequently (less than once a month), use new fuel with each use or add a stabilizing additive to the fuel tank.
1084_EN.docx
(G)
(D)
(E)
(H)
(F)
(I)
(A)
(M)
........................................
DIESEL 4000 E XL C5
3400 W
2720 W
92 dB(A)
0,69 dB(A)
KD350E_C5
RKDS1
Diesel
16 L
15W40
1,20 L
O
X
230V-11,8A
O
2 x 2P+T-230V-10/16A
A2
81 x 55,5 x 59 cm
84 kg
x: not available
.
(A):
Model
(B):
CE/EAC marking
(C):
Guaranteed acoustic
(J)
power level
(D):
Maximum power
(K)
(E):
Nominal power
(L)
(F):
Power factor
Engine manufacturer:(e.g.
Kohler)
DIESEL 6000 E XL C5
4900 W
4159 W
93 dB(A)
0,69 dB(A)
KD15-440E_C5
RKDS1
Diesel
16 L
5W40
1,50 L
O
X
230V-18,1A
O
1 x 2P+T-230V -10/16A /1 x
2P+T 230V-32A
A2
81 x 55,5 x 59 cm
103 kg
20/250
(G):
Ground
(H):
Current amperage
(I):
Current frequency
(J):
Current voltage
(K):
Protection rating
(L):
Reference standard
(M):
Serial number
Engine serial number: (e.g Kohler (SERIAL
NO. 4001200908))
......................................................
DIESEL 6500 TE XL C5
5200W
4159 W
93 dB(A)
0,69 dB(A)
KD15-440E_C5
RKDS1
Diesel
16 L
5W40
1,50 L
400V-6A
1 x 2P+T 230V-10/16A
/3P+T+N 400V-16A
A2
81 x 55,5 x 59 cm
108 kg
O
X
O
2020-08-14