6.2

Storage conditions

This procedure for storing the unit or protecting it over the winter must be respected if it is not used for a period of up to 1 year. For
longer periods of storage, it is recommended to contact your nearest agent or to start up the unit for a few hours every year,
ensuring that the storage procedure is respected afterwards.
1.
Start the unit and allow it to operate until it runs out of fuel.
2.
With the fuel tap open, replace the fuel filter (A15-C1).
The fuel circuit will drain, ensuring that the unit remains in good condition.
3.
Close the fuel tap (A7).
4.
Disconnect the battery (A2).
5.
Top up the oil.
6.
Replace the air filter (A16).
7.
Clean the unit and cover it with a protective cover.
8.
Store it in its normal position, in a clean, dry and well ventilated area.
7.1
Diagnostics for minor faults
The unit...
Does not start
Stops
Does not function normally
(noise, smoke, etc.)
Does not supply electrical
current
7.2
Generator Smart Care
If the unit has been equipped with the "GS101-Generator Smart Care" option (A19),
it is necessary to change the batteries in the Bluetooth GSC101 box when the
warning is displayed in the Generator Smart Care application (approximately every
two years).
1.
Use a small crosshead screwdriver to open the cover of the box,
2.
Remove the used batteries and take them to a waste collection point so
that they can be recycled,
3.
Fit two new AAA batteries, observing the polarity (+/-),
4.
Close the unit cover and carefully tighten the screws.
8.1
Operating conditions
The stated outputs of the units are obtained under the reference conditions outlined in ISO 8528-1(2005):
Total barometric pressure: 100 kPa - Ambient air temperature: 25°C (298 K) - Relative humidity: 30%.
The unit's output is reduced by approximately 4% for every additional 10°C and/or approximately 1% for every additional 100m in
altitude. Units can only operate while stationary.
1084_EN.docx
Check that:
The checks before starting have been
performed.
YES
The battery is correctly connected and
charged.
YES
The equipment to be used has not
been connected prior to starting.
YES
The APM202* fuses are not faulty (the
indicator lights come on).
YES
The oil level is correct.
YES
The fuel level is correct.
YES
Maintenance has been correctly
performed on the unit components.
YES
Have the unit checked by one of our
agents**.
Tripped circuit breaker(s).
YES
The connected devices and their power
cords are not faulty.
YES
Have the unit checked by one of our
agents**.
19/250
Section 7. Repairing minor faults
Solutions to be applied:
Perform the checks.
NO
Install the battery; replace it with a new
NO
battery if necessary.
Disconnect the equipment then try to start
the unit again.
NO
Have the unit checked by one of our
agents**.
NO
Top up with oil.
NO
Fill up with fuel.
NO
Perform maintenance on the unit as per
NO
the recommendations
Check the capacity of the unit and press
the circuit breakers.
NO
Try with another item of equipment and
another power cord.
NO
** France: 0.806.800.107 (call charge)