Herunterladen Inhalt Inhalt Diese Seite drucken

Preparations For Assembly; For Exhaust Air Operation; Connection For Power Supply - hanseatic SY-103E9A-P1-C84-L121-600 Gebrauchsanleitung

Kopffreihaube
Vorschau ausblenden Andere Handbücher für SY-103E9A-P1-C84-L121-600:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Preparations for assembly

For exhaust air operation

WARNING
Risk of suffocation/explosion!
Never attach the exhaust hood to a
ventilation shaft, chimney or smoke-
stack! The air being extracted must
not travel through a channel in which
warm air circulates. The extracted
air may only be released to the out-
side through a separate air channel
intended exclusively for the exhaust
hood.
NOTICE
Risk of damage to property!
We recommend having a specialist
carry out all preparations.
Before you can begin assembly, all of the fol-
lowing conditions must be met:
– There must be a wall or ceiling break of at
least 15.5 cm in diameter.
– If the exhaust air hose passes through an
exterior wall, the air outlet on the outside
must have a cover with self-opening slits
(not included in the package contents).
To keep subsequent energy usage as low as
possible, we recommend
– placing the exhaust air channels as straight
as possible and avoiding any sharp angles
(curves or bends are preferable). Each
bend increases energy usage.
– not reducing the cross-section of the fan
connector. The wider the diameter of the
exhaust air hose and the smoother its inte-
rior surface, the better the extraction func-
tion will be.
– selecting a ventilation conduit with exterior
shutters that can open completely during
use.
Preparations for assembly

Connection for power supply

WARNING
Risk of electric shock!
The mains plug must be as accessible
as possible during use, i.e. the plug
must be accessible even after the ex-
haust hood has been installed.
If the mains plug is no longer acces-
sible after installation, an all-poles
disconnecting device complying with
overvoltage category III must be
connected to the house wiring with a
contact gap of at least 3 mm; this in-
cludes fuses, circuit breakers and con-
tactors.
Electrical installation may be per-
formed only by a certifi ed specialist.
If an additional socket is required,
have an electrician perform the in-
stallation.
Do not connect to a multiple socket
outlet, power strip, timer or to a sepa-
rate remote-controlled system for dis-
tance monitoring and control.
To ensure that the exhaust hood will perform
optimally and that no obtrusive cabling is
visible, plan the connection for power sup-
ply carefully before installation: The exhaust
hood must be placed over the centre of the
cooking zone.
Page EN-13

Quicklinks ausblenden:

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis