- The ambient temperatures must not exceed the limit values spec-
ified in the table below.
- The transmitter must be set up in such a way as to provide at
least IP20 protection according to EN 60529, also for the con-
necting parts.
- During setting up and operation of the transmitter, any build-up of
electrostatic charge must be avoided.
Extract from the EC Type Examination Certificate
Marking
Temperature range
in II 2 G
and II 3 G
Temperature range
in II 1 G
Supply circuit
maximum values at
terminals 1(+) and 2(-)
internal inductance
and capacitance
Sensor current circuit
maximum values at
terminals 3, 4, 5 and 6
max. permissible external
inductance/capacitance
Ex ia IIC
Ex ia IIB
2 Safety notes
ZELM 99 ATEX 0018 X
T6: T
T5: T
T4: T
T6: T
T5: T
T4: T
U
I
i
P
L
C
U
I
o
P
L
L
5
II 1 G Ex ia IIC T6-T4 Ga
= -40 to +55°C
amb
= -40 to +70°C
amb
= -40 to +75°C
amb
= -40 to +40°C
amb
= -40 to +50°C
amb
= -40 to +60°C
amb
= 30VDC
i
= 100mA
= 750mW
i
= negligible
i
= negligible
i
= 9.6VDC
o
= 4.5mA
= 11mW
o
= 4.5mH / C
o
= 8.5mH / C
o
= 709nF
o
= 1300nF
o