Herunterladen Inhalt Inhalt Diese Seite drucken

Troubleshooting - VOLTCRAFT MT-52 Bedienungsanleitung

Multi-dmm
Vorschau ausblenden Andere Handbücher für MT-52:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Troubleshooting

In purchasing the DMM, you have acquired a product which has been designed to the state of the art and
is operationally reliable. Nevertheless, problems or errors may occur. For this reason, the following is a
description of how you can eliminate possible malfunctions yourself.
Always follow the safety instructions!
Error
The multimeter
does not work.
No measured value
change.
Repairs other than those described above may only be carried out by an authorised
specialist. If you have queries about handling the measuring device, our technical
support is available under the following telephone number:
Voltcraft®, 92242 Hirschau, Lindenweg 15, Tel.-No. 0180 / 586,582 7.
Possible cause
Is the battery dead?
Is a wrong measuring function
activated (AC/DC)?
Did you use the wrong
measuring sockets?
Is the fuse defect?
Is the "HOLD" function activated? Press the "HOLD" button.
Remedy
Check the status.
Replace batteries.
Check the display (AC/DC)
and switch the function
if applicable.
Compare the connection with the
information from the operating
instructions.
Check the fuses.
59

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis