Herunterladen Diese Seite drucken

Gude 20004 Originalbetriebsanweisung Seite 10

Elektrodenschweissgerät
Vorschau ausblenden Andere Handbücher für 20004:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Make sure no item causes short-circuit on appliance
contacts.
Lay all cables in a manner to prevent risk of trip and to
eliminate cable damage!
Wear protective clothing suitable for the given
environment the whole time you work and take suitable
preventive measures to prevent accidents.
Do not use the cable for any other purpose than
specified. Do not wear the cable by its cable and do
not use the cable for pulling the plug out of socket.
Protect the cable against excessive temperatures, oil
and sharp edges.
Be very careful of your appliance. Keep it clean so that
working with it is fine and safe. Regularly check the
plug and cable and have them repaired by an
authorised specialist if damaged. Regularly check the
extension cables and have any damaged cable
replaced by a specialist.
Extension cables to be used outdoors only. For
outdoor work, use extension cables adequately marked
and approved for that purpose (within 20 m ∅1.5 mm²,
20-50 m ∅ 2.5 mm²)
Unplug the appliance
- before every cleaning
- after each use
Persons unable to operate the appliance due to
their physical, sensory or mental abilities or their
inexperience or lack of knowledge must not operate
it.
If the appliance, feeder cable or steel cable show
any sign of visible damage the appliance must not
be put into operation.
If the feeder cable of the appliance is damaged it
needs to be replaced by the producer or an
electrician.
Repairs of the appliance can only be executed by
an electrician. There might be significant risks as a
result of unauthorised repairs.
The same regulations apply for accessories.
Güde GmbH & Co. KG does not answer for damages
caused by:
Appliance damage by mechanical influences and
overloading.
Any changes to the appliance.
Use for any other purpose than that described in
the Operating Instructions.
Unconditionally follow all safety instructions to
prevent accidents and damage.
Important safety Instructions
Always wear gloves of insulation fabric.
Wear suitable clothing, avoid any clothing of synthetic
material.
Wear heady-duty insulating shoes.
Make sure that working area is properly ventilated to
prevent accumulation of harmful fumes and toxic smoke
Never work in wet places without efficient safety
measures against electrical discharges
After the work, the electrode has to be taken from the
electrode tongs to prevent undesired arc formation.
The welding machine should not be used or stored in
rain.
If the unit is in operation, the electrode tongs should not
be put on the unit or other electric appliances as the
safety device may get damaged or disconnected when
grounded.
Do not touch the electrode or another metal object in
contact with the electrode while welding is in progress
Check that all cables are coated (mainly the contacts
with the power cable). The cables with insufficient
insulation should be immediately replaced with the same
size cables meeting the regulations.
Disconnect the unit from the source where not used.
The unit may influence supply of other units according to
characteristics of the mains. Seek advice from an
authority responsible for the power supply whenever in
doubt.
Assembly and Initial Operation
Fig. 2 Assembly Group 1: Fig. 1 – Pos. 2, Fig. 1 – Pos. 5, Fig.
1 – Pos. 6, Fig. 1 – Pos. 7
Fig. 3 Assembly Group 2: Fig. 1 – Pos. 2, Fig. 1 – Pos. 3 / 2x,
Fig. 1 – Pos. 4, Fig. 1 – Pos. 12
Fig. 4 Assembly Group 3: Fig. 1 – Pos. 8, Fig. 1 – Pos. 12
Fig. 5 Assembly Group 4: Fig. 1 – Pos. 9, Fig. 1 – Pos. 10,
Fig. 1 – Pos. 12
Initial Operation safety Instructions
Check the power supply for sufficient protection (16
A, inertial)
Wear required clothing (see Fig. 6)
Make sure that no other persons are present on the
working site or the area of hazard.
Take care for no inflammable material being on the
site.
Fig. 6
1.
welder´s helmet
2.
welder´s apron
3.
welder´s gloves
See also chapter Residual hazards and safety
measures and safety action arising therefrom.
Do not use the unit before you have read the instruction
manual.
Observe all the safety instruction contained herein.
Be responsible to other persons.
Operation
Fig. 7
1.
Thermal Protection indicator
2.
„Stand by" Indicator
3.
Welding degrees stop ring
4.
Earthing connection
5.
Electrode holder connection
6.
Voltage selector
Fig. 8
Having changed from 230 V to 400 V, take steps as
follows:
1.
Unplug the unit.
2.
Put the switch at „0".
3.
Remove the lock screw and fit it on the 400 V side.
4.
Before putting the unit in operation again, make sure that
the knob may be turn in position 400 V and cannot be
turned in position 230 V.
The unit may be used at a room temperature from 20°C
-
without the thermal protection being put on with the
number of reference electrodes n
condition without switching the thermal protection on.
The earthing tongs need to be connected with the piece
-
to be welded in a way providing for a good contact. The
touch points should be cleaned so that no grease or
other impurities that could adversely affect the welding
output are present.
The unit has a main switch, yellow light indicator,
-
thermal protection and a hand wheel to control the
welding current. The control is done with regard to
welding current valuea and electrode diameter.
10
; and n
from warm
0
h

Werbung

loading

Diese Anleitung auch für:

Ge 185 f