5.4
Mounting the C4000 Palletizer and C4000 Fusion with floor stands
6

Pin assignment

8028265/2023-03-23 | SICK
Subject to change without notice
The floor stand is suitable for mounting the C4000 horizontally. Depending on the
mounting method, you an implement installation heights from 70 to 430 mm or from
519 to 780 mm.
System connection M26 × 11 + FE
5
10
6
7
11
8
FE
4
3
2
9
1
Pin assignment for system connection M26 × 11 + FE
Pin
Wire color
s Sender
1
Brown
24 V DC input (voltage supply)
2
Blue
0 V DC (voltage supply)
3
Gray
Test input:
0 V: external test active
24 V: external test deactivated
4
Pink
Reserved
5
Red
Reserved
6
Yellow
Reserved
7
White
Reserved
8
Red/blue
Reserved
9
Black
Device communication (EFI
10
Violet
Device communication (EFI
11
Gray/pink
C4000 Standard and C4000
Advanced: Input for Host/Guest
SEL
All other variants: Reserved, do
not use
FE
Green
Functional earth
MOUNTING INSTRUCTIONS
1
9
2
3
4
FE
8
11
7
6
10
5
r Receiver
24 V DC input (voltage supply)
0 V DC (voltage supply)
OSSD1 (switching output 1)
OSSD2 (switching output 2)
Reset/restart
External device monitoring (EDM)
Application diagnostic output (ADO)
Output for reset required
)
Device communication (EFI
A
)
Device communication (EFI
B
C4000 Standard and C4000
Advanced: Input for Host/Guest
SEL
All other variants: Reserved, do
not use
Functional earth