Herunterladen Inhalt Inhalt Diese Seite drucken

Dimplex DHW 301P Montage- Und Gebrauchsanweisungen Seite 59

Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

Operation
10.12.2.4. Load shedding – Enable levels at peak
load times "SHEDDING"
If the load shedding contact is active at peak load
times, this setting can be used to block the heat pump
and/or the additional heating element.
s h ed di n g
1
If the load shedding contact is open, the following
settings are possible:
Heat pump and additional heating element
Mode 1:
are blocked
Function enabled for heat pump only
Mode 2:
Function enabled for electric additional
Mode 3:
heating element only
Function enabled for heat pump and addi-
Mode 4:
tional heating element (= neutralisation of
"Peak load times" function).
If the PV function is enabled, this function
is disabled. In this case, a time program
should be set up (see "Setting a weekly
program" chapter).
Press the
button to return to the home screen.
10.12.2.5. Maximum heating-up time "MAX. TIME"
The maximum heating-up time can be used to adjust
the period for complete filling of the cylinder for a
specific user. In this case, the heat pump control auto-
matically enables the supplementary electric heating
to speed up heating-up of the cylinder.
max. time
no
NOTE
Selecting "MAX. TIME" = "AUTO" limits the heating-up
time to 5 hours.
NOTE
For energy use reasons, the heating-up time for com-
plete discharge of the cylinder with domestic hot
water should not be less than 7 hours.
This function is disabled by default.
Press the
button to return to the home screen.
www.dimplex.de
Select mode
s h e d d in g
0
Confirm
max. time
3h
Confirm
10.12.3. Key lock
Automatic and permanent locking
In the "LOCKING" menu, 3 possible locking options
for access to the menus can be set.
In the "INST. MENU", turn the dial to "LOCKING".
Locking is not enabled. However, manual
No:
locking is possible.
To do this, press and hold the
three seconds.
To unlock, press and hold the
three seconds, until "UNLOCK" appears in the
display. Confirm "YES" by pressing the button.
locking
Auto:
The key lock is automatically enabled after 60
seconds. To unlock, press and hold the
button for three seconds, until "UNLOCK"
appears in the display. Confirm "YES" by
pressing the button.
50°
The key lock is automatically enabled after 5
Pro:
minutes. To unlock, press and hold the
button for three seconds, until "UNLOCK"
appears in the display. Then simultaneously
press and hold the
"UNLOCK" appears in the display. Confirm
"YES" by pressing the button.
50°
+
Press for 3 seconds
NOTE
When the key lock is enabled, only fault messages can
be reset.
FD 0303
Select lock level
lo c k i ng
n o
Select „Yes"
unlock
C
ye s
and
buttons until
unlock
C
no
Select „Yes"
unlock
yes
Confirm
English
button for
button for
Confirm
Confirm
EN-23

Quicklinks ausblenden:

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Dhw 301p+