Symptoms
Circuit breaker (fuse) has tripped
ALWAYS MAKE SURE TO USE ORIGINAL PARTS AND ACCESSORIES.
4.5

Maintenance and service instructions

Note
All maintenance and service work should be carried out at least according to
care
plan".
Compressed air maintenance unit
Setting the working pressure
Check the working pressure displayed in the
pressure gauge
. This must correspond to the
technical data.
The working pressure can be adjusted using the
pressure regulator
Pull the pressure regulator up to make adjustments.
To increase the pressure in the machine, turn the
regulator clockwise. To decrease the pressure, turn
the regulator counterclockwise.
Oiler
Check the oil level in the oil reservoir
Remove the oil reservoir.
Now refill the reservoir with a pneumatic oil of
SAE20 viscosity accordingly.
Check the injection quantity of the oiler through the
sight glass
.
As a rule, the screw
by turning clockwise and then opened again by
approx. 1/4 to 1/2 turn by turning counterclockwise.
Water separator
Check the water level in the separator
Open the valve
to drain the water.
® Copyright ATH-Heinl GmbH & Co. KG / All rights reserved / Misprints and technical changes reserved
120
Cause
Check the contacts on the
contactor
Check the capacity of circuit
breakers
Check for damage to the cable
.
.
must be closed completely
.
Release date: 16.03.2023 / Product manufacturer ATH-Heinl GmbH & Co. KG
Solution
Replace the contactor
Replace the fuses
Replace the cable