Herunterladen Inhalt Inhalt Diese Seite drucken

ATH Four Lift 55HAP Bedienungsanleitung Seite 100

4-säulen-hebebühne
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Attention
Do NOT operate the pump-motor unit without oil.
Otherwise, damage to the pump may occur. If the motor becomes hot or makes strange
noises, stop immediately and recheck the electrical connection.
Observe the direction of rotation of the motor. When the LIFT button is pressed, the motor fan wheel must
rotate in the direction indicated. The unit must start to pump oil after approx. 15 seconds. If not, the direction
of rotation must be changed.
At the following points, all columns must be closely observed during the entire process
Press the LIFT button, after a short time the cylinder fills with oil and tightens the lifting ropes
Lift the platform until the crossbars are approx. 50 mm above the trestles or squared lumber.
Align the columns to the crossbeam using a spirit level
Attach a safety anchor to each column for safety reasons
Remove the trestles or squared lumber.
Move the lifting platform to the lowest position by pressing the LOWER button.
Now check the position of the columns again and attach the remaining safety anchors as described in the
next step.
Check the dimensions against the floor plan and make sure that the base plate of each column is flat on the
floor and that the column is aligned squarely
Use the base plate as a guide and drill each hole with a hammer drill
2.9.2.6
Fastening by means of safety anchor
® Copyright ATH-Heinl GmbH & Co. KG / All rights reserved / Misprints and technical changes reserved