5. Tighten the screw again after the trapped air has escaped.
2.9.2.12
Installation of the CE stop switch
1. Raise the lifting platform to a height of 380 mm
2. Mount the CE-Stop switch on the main column and check that it can be operated from the bottom of the
crossbeam.
3. Perform the entire cycle of lowering and raising to verify proper installation and ensure that the alarm is
heard during the final lowering phase. If necessary, adjust the switch by changing the position of the switch
lever.
1
CE stop switch
Shift lever
® Copyright ATH-Heinl GmbH & Co. KG / All rights reserved / Misprints and technical changes reserved