CONNECT THE CABLE TO THE OUTDOOR UNIT

5
(FOR DETAIL REFER TO WIRING DIAGRAM AT UNIT)
1. Remove the control board cover from the unit by loosening the screw.
2. Connecting cable between indoor unit and outdoor unit shall be approved polychloroprene sheathed fl exible cable (see below table), type
designation 60245 IEC 57 or heavier cable.
3. Secure the cable onto the control board with the holder (clamper).
4. Attach the control board cover back to the original position with screw.
WARNING
This equipment must be properly earthed.
Models
WH-UXZ09KE5*,
WH-UXZ12KE5*
Terminals on the indoor unit
Colour of wires
Terminals on the outdoor unit
Select required direction and apply protective bushing
provided in accessories to protect cables from sharp edges.
Once all wiring work has been completed, tie the cable and
cord together with the binding strap so that they do not touch
other parts such as the compressor and bare copper pipes.
Outdoor Unit
Protective
bushing 3
Apply cut
DETAIL OF CONNECTING CABLE GUIDING
10
Flexible cable specifi cation
4 x min 4.0 mm
2
1
2
3
1
2
3
Earth Wire
must be
longer than
others cables
for safety
reason.
Indoor/outdoor unit
terminal board
Cord clamp
Banding strap
(Field Supply)
Connecting cable
(refer below
diagram for its
guiding)
Selection
of direction
WIRE STRIPPING AND CONNECTING REQUIREMENT
Wire stripping
Indoor/outdoor
connecting terminal
board
No loose strand when insert
Conductor over
Conductor fully
insert
ACCEPT
PROHIBITED

PIPE INSULATION

6
1. Please carry out insulation at pipe connection portion as
mentioned in Indoor/Outdoor Unit Installation Diagram. Please
wrap the insulated piping end to prevent water from going inside
the piping.
2. If drain hose or connecting piping is in the room (where dew may
form), please increase the insulation by using POLY-E FOAM
with thickness 6 mm or above.
If cleaning of the outdoor unit is necessary during installation
or servicing, do not clean the outdoor unit with any
hydrocarbon based solvent.
5 mm or more
(gap between wires)
Conductor not
insert
fully insert
PROHIBITED
CAUTION