Herunterladen Diese Seite drucken

Bergstrom IRIS Diagnose Bei Ausfällen Seite 8

Vorschau ausblenden Andere Handbücher für IRIS:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

IRIS
EN
8
TU ESPACIO DE VIDA CONFORTABLE
TROUBLESHOOTING
MANUAL DE USUARIO
Symptom
System does not work. No air is
A
coming out through air vents.
System does not cool or cools
B
insufficiently.
Water over flows and comes out of
C
front air vents.
Fan making excessive noise.
D
Fan works by itself, without acting
E
on control.
Electronic module is burnt when
F
system is switched on.
Water gets in through union
G
between equipment and cabin.
Water does not reach the evaporation
H
unit.
Cause
• Fan does not work.
• No water, or not enough water, reaches
wet filter.
• Level sensors do not cut off electrovalve
current.
• Electrovalve does not cut off the water flow.
• Water level cabling does not send current
to the electrovalve.
• Faulty fan.
• Electronic module damaged by water
inlet.
• Current outlet badly connected to battery.
• Faulty sealing of joints.
• Original water pressure system of caravan
works thanks to electronic taps. Therefore,
there is only pressure when a tap is open.