Total 250 g
Clear total?
Fig. 9.7
Flowchart for monitoring setpoint value and weighing
Checkweighing is activated as soon as the scale is loaded with no more than 10 % of the
setpoint value and the idle state is detected. After this, the corresponding output signal is
set and retained until the weight on the scale falls below 10 % of the setpoint value once
more. Then the output signal is reset and a new check cycle can begin.
S
If an optical tilt sensor is connected, Input 2 is no longer available for operating
mode functions.
S
You can lock the Totalize (With totals?) function via Supervisor Mode; see section
7.3, page 70.